Burnout oven when rewinding a motor: protecting the core at 360 °C
Short answer
To rewind, the old winding is burned off in an oven, but the core has laminations with very thin insulation between them. If they overheat, losses rise and the motor runs hotter. The reference EASA cites for organic interlaminar insulation is not exceeding 360 °C. That's why the oven is controlled and the core is tested before and after.
Key points
- The old winding is burned off in an oven.
- Core laminations have very thin insulation between them.
- Overheating raises losses and the motor runs hotter.
- EASA cites 360 °C for organic interlaminar insulation.
- The core is tested before and after the rewind.
Transcript
Why can a rewound motor come out worse than before? It's not the new copper, it's the core. To rewind, the old winding is burned off in an oven, but the core has laminations with very thin insulation between them. Like baking bread at full heat: it looks the same outside, but inside it's ruined. If the laminations overheat, losses rise and the motor runs hotter. The reference EASA cites for organic interlaminar insulation is not exceeding 360 °C. But careful, a damaged core isn't fixed by a good winding. That's why the oven is controlled and the core is tested before and after. So it's not just rewinding, it's protecting the core. Was your core tested? Comment CORE and we'll tell you what to check.
Frequently asked questions
What temperature should the oven not exceed?
The video cites the EASA reference for organic interlaminar insulation: 360 °C.
Does a good winding fix a damaged core?
No, which is why the core is tested before and after.
Does TEMISA test the core when rewinding?
Yes, at the Tlajomulco shop. Email ventas@temisa.mx.
Related
Video with images and narration generated with AI.
Request a quotation by email: ventas@temisa.mx. Phone: +52 33 3614 2460.
More videos
- Medium voltage motor rewinding after a ground fault
- Industrial electric motor repair for a volute pump
- Dynamic balancing services for electric motors, ISO 21940
- Squirrel cage rotor repair for broken bars
- Locomotive traction motor repair: the commutator
- Emergency motor repair, on site or in the shop
- Induction motor slip: why it never reaches 1,800 rpm
- Motor starting current: 6 to 7 times rated, for seconds
- Synchronous motor and power factor: a motor that supplies reactive power
- High megger, damp motor: what the polarization index shows
- Motor running hot: 10 extra degrees, half the life
- Motor hipot test: why a 4,160 V motor gets 9,320 V
- Form-wound coil surge test: IEEE 522